Kennedy Valve recommends following AWWA Manual M17 Fire Hydrants, Installation, Field Testing & Maintenance.
Warning: Special care should be taken in the installation, inspection, testing, maintenance, and repair of pressure containing devices such as valves and hydrants. To prevent bodily injury, property damage, or damage to the fire hydrant and its supporting structures, use only a diffuser or flexible hose (properly restrained at the point of discharge) for flushing or flow testing. FAILURE TO FOLLOW PROPER PRACTICES AND GUIDELINES CAN RESULT IN SERIOUS BODILY INJURY OR DEATH. K17-Monitor-HW.jpg
Additional end conditions beyond those depicted are available - please contact knv.sales@mcwane.com C509-Product-Image-v2.jpg
Additional end conditions beyond those depicted are available - please contact knv.sales@mcwane.com C509-Product-Image-v2.jpg
Additional end conditions beyond those depicted are available - please contact knv.sales@mcwane.com C509-Product-Image-v2.jpg
Additional end conditions beyond those depicted are available - please contact knv.sales@mcwane.com C509_515-OSY-Handwheel.jpg
All figure types are offered with a visual vane and wired supervisory switch and available in either an open or closed position. Actuators are rated IP65.
They are constructed of durable ductile iron or bronze for a lightweight superior product. We utilize stainless steel shafts as well as EPDM encapsulated discs. Our fusion bonded or nylon coated bodies offer a superior long-lasting coating.
All XBFV valves have large diameter replaceable handwheels and switches to maintain system continuity during service and maintenance.
Manufacturing Standards - ISO 9001, ISO 14001, ISO 45001. XBFV.png
Note: If customer determines that the valve must also meet NSF 61/372 then contact KV Sales for a specially-ordered valve. G300-Straight-Leg.jpg
Note: If customer determines that the valve must also meet NSF 61/372 then contact KV Sales for a specially-ordered valve. W300-Straight-Leg.jpg
Note: 4” 806 Wafer shown in picture, 6” and 8” not offered with tap and plug. Wafer-Check-Valves-Figure-806.JPG
Industrial Fire Hydrant, K17 UL/ULC FM Rated
(18)Patent # 9,260,840 and # 9,260, 844
Kennedy Valve Company, with manufacturing experience dating back to 1905, is proud to introduce our newest and most innovative hydrant design. The K17 is among the highest performing hydrants available. The patented design incorporates features that include a 350 PSI working pressure rating, a true 6” flow. path and is shaped for optimal performance and “near laminar” flow. The K17 is a reliable, simple design, easy to install and easy to maintain type hydrant.Kennedy Valve recommends following AWWA Manual M17 Fire Hydrants, Installation, Field Testing & Maintenance.
Warning: Special care should be taken in the installation, inspection, testing, maintenance, and repair of pressure containing devices such as valves and hydrants. To prevent bodily injury, property damage, or damage to the fire hydrant and its supporting structures, use only a diffuser or flexible hose (properly restrained at the point of discharge) for flushing or flow testing. FAILURE TO FOLLOW PROPER PRACTICES AND GUIDELINES CAN RESULT IN SERIOUS BODILY INJURY OR DEATH. K17-Monitor-HW.jpg
200 psi UL Listed FM Approved Resilient Wedge Gate Valve, Thick Wall, Series 8000
Kennedy Valve Series 8000 Resilient Wedge Gate Valves are UL-262/FM-1120/1130, ULC - Underwriters’ of Canada as KS-FW, and NSF Certified. They are available in either non-rising stem (NRS) or outside screw & yoke (OS&Y). NRS style is available with post plate for adaptation with an indicator post. They are also compliant with AWWA C509 and cast of gray iron. OS&Y gate valves enjoy 3 to 10 times less friction loss than comparable UL-FM butterfly valves. OS&Y gate valves also offer a superior means to avoid water hammer upon closing the valve.Additional end conditions beyond those depicted are available - please contact knv.sales@mcwane.com C509-Product-Image-v2.jpg
200 psi UL Listed FM Approved Resilient Wedge Gate Valve, Series 7000
Kennedy Valve Series 7000 Resilient Wedge Gate Valves meet or exceed the requirements of AWWA standard C515, and are UL-262/FM-1120/1130, ULC - Underwriters’ of Canada as KS-RW 4” and larger and KS-FW 3” and down, and NSF Certified. Available in either non-rising stem (NRS) or outside screw & yoke (OS&Y). NRS style is available with post plate for adaptation with an indicator post. They are cast of ductile iron. OS&Y gate valves enjoy 3 to 10 times less friction loss than comparable UL-FM butterfly valves. OS&Y gate valves also offer a superior means to avoid water hammer upon closing the valve.Additional end conditions beyond those depicted are available - please contact knv.sales@mcwane.com C509-Product-Image-v2.jpg
350 psi UL Listed FM Approved Resilient Wedge Gate Valve, Series 5000
Kennedy Valve Series 5000 Resilient Wedge Gate Valves meet or exceed the requirements of AWWA standard C515, UL-262/FM-1120/1130, ULC - Underwriters’ of Canada and are UL Listed and FM Approved as KS FW-HP and KS RW-HP, and NSF Certified. Available in either non-rising stem (NRS) or outside screw & yoke (OS&Y). NRS style is available with post plate for adaptation with an indicator post. High Pressure Gate Valves are rated and tested for 350 psi. They are cast of ductile iron. OS&Y gate valves enjoy 3 to 10 times less friction loss than comparable UL-FM butterfly valves. OS&Y gate valves also offer a superior means to avoid water hammer upon closing the valve.Additional end conditions beyond those depicted are available - please contact knv.sales@mcwane.com C509-Product-Image-v2.jpg
UL/ULC Listed Factory Installed OS&Y Tamper Switch KVOS2
The KVOS2 is the only UL Listed factory installed tamper switch. It is the most robust and durable switch in the market. Installation only requires connect the low voltage wiring from the system panel.Additional end conditions beyond those depicted are available - please contact knv.sales@mcwane.com C509_515-OSY-Handwheel.jpg
UL/ULC Listed and FM Approved Indicator & Wall Posts
(29) Kennedy Valve's Indicator Posts provide the reliable way of operating a buried or inaccessible gate valve for opening or closing purposes. Kennedy Valve Indicator Posts come with a hand wheel. As an option an "L" shaped handle is available which can be fitted with a secure lock. Several models are available. The 2945A post has a telescoping barrel and is adjustable to meet various trench depths. The model 2945 is a fixed length option made to specified lengths. The 2945W is usually utilized on exterior wall applications. * The 2945P (Pit Post) is utilized when the post is desired to be mounted on a level higher than the valve resides. * Angle gear kits are available by contacting the company. ULFM-Indicator-Posts.JPGXBFV Grooved BFVs 1" - 12" UL Listed and FM Approved
(48) Designed for trouble-free reliability, Kennedy Valve’s UL Listed and FM Approved XBFV and BB Butterfly valves are ideal for use in fire protection systems. Kennedy’s butterfly valves offer slow closing utilizing smooth gear operators.All figure types are offered with a visual vane and wired supervisory switch and available in either an open or closed position. Actuators are rated IP65.
They are constructed of durable ductile iron or bronze for a lightweight superior product. We utilize stainless steel shafts as well as EPDM encapsulated discs. Our fusion bonded or nylon coated bodies offer a superior long-lasting coating.
All XBFV valves have large diameter replaceable handwheels and switches to maintain system continuity during service and maintenance.
Manufacturing Standards - ISO 9001, ISO 14001, ISO 45001. XBFV.png
UL/ULC Listed and FM Approved Grooved BFVs
(5) Designed for years of trouble free reliability, Kennedy UL-FM butterfly valves are constructed of durable ductile iron for a lightweight superior product. We utilize stainless steel upper and lower shafts as well as EPDM encapsulated discs. Our fusion bonded coated bodies offer a superior long-lasting coating. The valves are slow operating with low torque leading to excellent high cycle life. Our butterfly valves are always rated to 300psi and all are fully hydrostatically tested before they leave Elmira, NY.Note: If customer determines that the valve must also meet NSF 61/372 then contact KV Sales for a specially-ordered valve. G300-Straight-Leg.jpg
UL/ULC Listed and FM Approved Grooved Long Body BFV, USC Accepted for Cross Connection
(5) The G300E is a long body variant of our grooved butterfly valve family. It is an excellent choice for OEM applications, fire protection applications, and back flow applications where its four ¾” factory taps can be utilized. The G300E like the G300 is available as both a supervised open and supervised closed product. It is also NSF 61 approved when specified at the time of order. G300Es are USC cross connect rated for backflow use. All other features and construction are similar to the G300. G300E-Straight-Leg.jpgUL/ULC Listed and FM Approved Wafer BFV
(5) Designed for years of trouble free reliability, Kennedy UL-FM butterfly valves are constructed of durable ductile iron for a lightweight superior product. We utilize stainless steel upper and lower shafts as well as EPDM encapsulated discs. Our fusion bonded coated bodies offer a superior long-lasting coating. The valves are slow operating with low torque leading to excellent high cycle life. Our butterfly valves are always rated to 300psi and all are fully hydrostatically tested before they leave Elmira, NY.Note: If customer determines that the valve must also meet NSF 61/372 then contact KV Sales for a specially-ordered valve. W300-Straight-Leg.jpg
Normally Closed Butterfly Valves 2 1/2 - 8"
The Normally Closed Butterfly Valves have been added to our product offerings to satisfy the installation requirements associated with fire pump metering test lines, per NFPA 20 as well as rooftop test units. Additionally the Normally Closed Butterfly Valves may be utilized on pressure reducing valve by-pass lines per NFPA 14. Grooved-BUTTERFLY-VALVES-2-1_2-8.jpgUL/ULC Listed and FM Approved Flanged Check Valves
(14) Kennedy Swing Check Valves are for use to ensure flow in one direction. The bronze-to-bronze seat (1126) is designed with ample material to compensate for seat ring wear. The rotating action of the disc creates a self-cleaning effect that cleans the seat ring of foreign particles. The disc is also self-adjusting. The resilient seated (1126A) offers bubble-tight seating and is factory-tested. Kennedy UL / FM / ULC check valves can be installed in the horizontal or vertical orientation (with flow direction upwards). The 1126 and 1126A are available tapped for easy installation of gauges at up to six locations. Our modern cover design allows for simple inspection and service utilizing a tapped body, eliminating nut and bolt combinations seen on older products. We also use an o-ring system for modern and superior cover seating performance. Check-Valves---Series-1126.JPGUL/ULC Listed and FM Approved Grooved Check Valve
(5) The Kennedy Valve Figure 726 is a ULFM-approved Grooved End Check Valve. It is a lightweight unit that is intended to be easily installed with approved IPS grooved couplings. They may be installed either with the flow in a vertical position (flow up) or horizontally Upon request valves can have a 1/2” NPT connection on the inlet side for installation of a 1/2” ball drip. 726-Check-Valve.JPGUL/ULC Listed and FM Approved Wafer Check Valves
(3) Our 4, 6 and 8" wafer checks are industry-leading designs that offer built-in resilient seating performance for the installer. Each valve is manufactured with integral O-ring seals as part of its end condition. Flange gaskets are not required. If being installed with a groove flange adapter, a simple washer can be inserted to provide easy seating and installation. Contact grooved manufacturer for washer information. Spring-loaded, the Kennedy wafer check can be installed easily in either the horizontal or vertical (anti-water hammer). This valve is an absolute must for limited-space installs. Only the 4” wafer includes a tap and plug.Note: 4” 806 Wafer shown in picture, 6” and 8” not offered with tap and plug. Wafer-Check-Valves-Figure-806.JPG